Fluid Catalytic Cracking (FCC) is the conversion process used in petroleum refineries to convert the high-boiling point, high-molecular weight hydrocarbon fractions of petroleum (crude oils) into gasoline, alkene gases, and other petroleum products. The cracking of petroleum hydrocarbons was originally done by thermal cracking, now virtually replaced by catalytic cracking, which yields greater volumes of high octane rating gasoline; and produces by-product gases, with more carbon-carbon double bonds (i.e. alkenes), that are of greater economic value than the gases produced by thermal cracking.

The feedstock to the FCC conversion process usually is heavy gas oil (HGO), which is that portion of the petroleum (crude oil) that has an initial boiling-point temperature of or higher, at atmospheric pressure, and that has an average molecular weight that ranges from about 200 to 600 or higher; heavy gas oil also is known as “heavy vacuum gas oil” (HVGO). In the fluid catalytic cracking process, the HGO feedstock is heated to a high temperature and to a moderate pressure, and then is placed in contact with a hot, powdered catalyst, which breaks the long-chain molecules of the high-boiling-point hydrocarbon liquids into short-chain molecules, which then are collected as a vapor.

Fluid catalytic cracking

Economics

Oil refineries use fluid catalytic cracking to correct the imbalance between the market demand for gasoline and the excess of heavy, high boiling range products resulting from the distillation of crude oil.

Fluid catalytic cracking

As of 2006, FCC units were in operation at 400 petroleum refineries worldwide, and about one-third of the crude oil refined in those refineries is processed in an FCC to produce high-octane gasoline and fuel oils. During 2007, the FCC units in the United States processed a total of of feedstock per day, and FCC units worldwide processed about twice that amount.

Fluid catalytic cracking

FCC units are less common in Europe, the Middle East and Africa (EMEA) because those regions have high demand for diesel and kerosene, which can be satisfied with hydrocracking. In the US, fluid catalytic cracking is more common because the demand for gasoline is higher.

Flow diagram and process description

The modern FCC units are all continuous processes which operate 24 hours a day for as long as 3 to 5 years between scheduled shutdowns for routine maintenance.

There are several different proprietary designs that have been developed for modern FCC units. Each design is available under a license that must be purchased from the design developer by any petroleum refining company desiring to construct and operate an FCC of a given design.

There are two different configurations for an FCC unit: the "stacked" type where the reactor and the catalyst regenerator are contained in two separate vessels, with the reactor above the regenerator, with a skirt between these vessels allowing the regenerator off-gas piping to connect to the top of the regenerator vessel, and the "side-by-side" type where the reactor and catalyst regenerator are in two separate vessels. The stacked configuration occupies less physical space of the refinery area. These are the major FCC designers and licensors:

Side-by-side configuration: Lummus Technology ExxonMobil Research and Engineering (EMRE) Shell Global Solutions Axens / Stone & Webster Process Technology — currently owned by Technip UOP LLC - A Honeywell Company

Stacked configuration: Kellogg Brown & Root (KBR)

Each of the proprietary design licensors claims to have unique features and advantages. A complete discussion of the relative advantages of each of the processes is beyond the scope of this article.

Reactor and regenerator

The reactor and regenerator are considered to be the heart of the fluid catalytic cracking unit. The schematic flow diagram of a typical modern FCC unit in Figure 1 below is based upon the "side-by-side" configuration. The preheated high-boiling petroleum feedstock (at about 315 to 430 °C) consisting of long-chain hydrocarbon molecules is combined with recycle slurry oil from the bottom of the distillation column and injected into the catalyst riser where it is vaporised and cracked into smaller molecules of vapour by contact and mixing with the very hot powdered catalyst from the regenerator. All of the cracking reactions take place in the catalyst riser within a period of 2–4 seconds. The hydrocarbon vapours "fluidize" the powdered catalyst and the mixture of hydrocarbon vapors and catalyst flows upward to enter the reactor at a temperature of about 535 °C and a pressure of about 1.72 bar.