+-----------+--------------+-------------+--------+--------------------+ | | Response | Response | | | | Intensity | (Light | (Light | Mean | Value in volt | | of Light | diminishing) | increasing) | | | +-----------+--------------+-------------+--------+--------------------+ | 7 | 43 | 39 | 41 | 63·0 × 10^{ -} volt | | 5 | 31 | 29 | 30 | 46·1 × " | | 3 | 18·5 | 17·5 | 18 | 27·7 × " | | 1 | 10 | 9 | 9·5 | 14·6 × " | +-----------+--------------+-------------+--------+--------------------+

As the zero point was slightly shifted during the course of the experiment, the deflection in each curve was measured from a line joining the beginning of the response to the end of its recovery. A mean deflection, corresponding to each intensity, was obtained by taking the average of the descending and ascending readings. The two sets of readings did not, however, vary to any marked extent.

Response in the Living and Non-Living — Part 88

The deflections corresponding to the intensities 1, 3, 5, 7, are, then, as 9·5 to 18, to 30, to 41. If the deflections had been strictly proportionate to the intensities of light stimulus they would have been as 9·5 to 28·5, to 47·5, to 66·5.

Response in the Living and Non-Living — Part 88

[Illustration: FIG. 104.--CURVES GIVING THE RELATION BETWEEN INTENSITY OF LIGHT AND MAGNITUDE OF RESPONSE In (_a_) sensitive cell, (_b_) in frog's retina.]

Response in the Living and Non-Living — Part 88

In another set of records, with a different cell, I obtained the deflections of 6, 10, 13, 15, corresponding to light intensities of 3, 5, 7, and 9.

The two curves in fig. 104, giving the relation between response and stimulus, show that in the case of inorganic substances, as in the retina (Waller), magnitude of response does not increase so rapidly as stimulus.

#After-oscillation.#--When the sensitive surface is subjected to the continued action of light, the E.M. effect attains a maximum at which it remains constant for some time. If the exposure be maintained after this for a longer period, there will be a decline, as we found to be the case in other instances of continued stimulation. The appearance of this decline, and its rapidity, depends on the particular condition of the substance.

When the sensitive element is considerably strained by the action of light, and if that light be now cut off, there is a rebound towards recovery and a subsequent after-oscillation. That is to say, the curve of recovery falls below the zero point, and then slowly oscillates back to the position of equilibrium. We have already seen an instance of this in fig. 102. Above is given a series of records showing the appearance of decline, from too long-continued exposure and recovery, followed by after-oscillation on the cessation of light (fig. 105). Certain visual analogues to this phenomenon will be noticed later.