The vessels and nerves of the leg are seldom seriously damaged.

_Treatment._--If there is marked displacement, reduction is most satisfactorily accomplished under anæsthesia. Traction is made upon the foot and the fragments are manipulated into position, the pointing of the toes and the outward rotation of the foot being at the same time corrected. The normal outline of the foot in relation to the leg is restored when the ball of the great toe, the medial malleolus, and the medial edge of the patella are in the same vertical plane. As in other fractures of the lower extremity, the limb should be placed in the natural position of slight eversion: not with the toes pointing straight forward.

Manual of Surgery Volume Second: Extremities--Head--Neck. Sixth Edition. — Part 141

The retentive apparatus to be applied depends upon the tendency to re-displacement, the degree of swelling, and the extent of the damage to the skin.

Manual of Surgery Volume Second: Extremities--Head--Neck. Sixth Edition. — Part 141

In the average case, the leg is supported between sand-bags, and massage and movements are employed from the outset. When there is a tendency to re-displacement, the limb may be immediately enclosed in a rigid apparatus, such as lateral poroplastic splints retained in position by an elastic bandage, or a Cline's splint, which can readily be removed to admit of massage. When the fracture is in the lower third of the leg, the ambulatory splint gives excellent results, and is of special service in hospital practice (Fig. 95).

Manual of Surgery Volume Second: Extremities--Head--Neck. Sixth Edition. — Part 141

As an emergency appliance, for example for purposes of transport, the _box splint_ (Fig. 91) is simple and efficient. We have not found it effectual in controlling the fragments, particularly in oblique fractures, and it requires constant supervision and readjustment. It consists of two pieces of wood extending from above the knee to an inch or two beyond the sole, and a little broader than the maximum diameter of the leg. These are rolled into the opposite ends of a folded sheet, so as to form two sides of a box, of which the sheet constitutes a third side. It is found advantageous to insert another board, fitted with a foot-piece, between the folds of the sheet forming the third side of the box, to add to the rigidity of the splint, and to aid in controlling the foot. By folding one side of the sheet somewhat obliquely, the box is made a little wider at the knee than at the ankle, and so fits the limb more accurately.