It must be noted, however, that this final stage in the liquefaction struggle was not effected through the use of the principle of evaporating liquids which has just been referred to, but by the application of a quite different principle and its elaboration into a perfectly novel method. This principle is the one established long ago by Joule and Thomson (Lord Kelvin), that compressed gases when allowed to expand freely are lowered in temperature. In this well-known principle the means was at hand greatly to simplify and improve the method of liquefaction of gases, only for a long time no one recognized the fact. Finally, however, the idea had occurred to two men almost simultaneously and quite independently. One of these was Professor Linde, the well-known German experimenter with refrigeration processes; the other, Dr. William Hampson, a young English physician. Each of these men conceived the idea--and ultimately elaborated it in practice--of accumulating the cooling effect of an expanding gas by allowing the expansion to take place through a small orifice into a chamber in which the coil containing the compressed gas was held. In Dr. Hampson's words:
"The method consists in directing all the gas immediately after its expansion over the coils which contain the compressed gas that is on its way to the expansion-point. The cold developed by expansion in the first expanded gas is thus communicated to the oncoming compressed gas, which consequently expands from, and therefore to, a lower temperature than the preceding portion. It communicates in the same way its own intensified cold to the succeeding portion of compressed gas, which, in its turn, is made colder, both before and after expansion, than any that had gone before. This intensification of cooling goes on until the expansion-temperature is far lower than it was at starting; and if the apparatus be well arranged the effect is so powerful that even the smaller amount of cooling due to the free expansion of gas through a throttle-valve, though pronounced by Siemens and Coleman incapable of being utilized, may be made to liquefy air without using other refrigerants."
So well is this principle carried out in Dr. Hamp-son's apparatus for liquefying air that compressed air passing into the coil at ordinary temperature without other means of refrigeration begins to liquefy in about six minutes--a result that seems almost miraculous when it is understood that the essential mechanism by which this is brought about is contained in a cylinder only eighteen inches long and seven inches in diameter.