where _N_{ t}_ is the number of emanation particles present at the time _t_, _N₀_ the number present when radio-active equilibrium is reached, and λ is the radio-active constant of the emanation. The phosphorescent action, which is due partly to the radiations from the emanation and partly to the excited activity on the walls, should thus reach half the maximum value in four days and should practically reach its limit after three weeks’ interval.

The variation of luminosity with different distances between the screens is to be expected. The amount of excited activity deposited on the boundaries is proportional to the amount of emanation present. Since the emanation is equally distributed, the amount of excited activity deposited on the screens, due to the emanation between them, varies directly as the distance, provided the distance between the screens is small compared with their dimensions. Such a result would also follow if the phosphorescence were due to the radiation from the emanation itself, provided that the pressure of the gas was low enough to prevent absorption of the radiation from the emanation in the gas itself between the screens.

Radio-Activity — Part 191

=149. Emanating power.= The compounds of thorium in the solid state vary very widely in the amount of emanation they emit under ordinary conditions. It is convenient to use the term _emanating power_ to express the amount of emanation given off per second by one gram of the compound. Since, however, we have no means of determining absolutely the amount of emanation present, all measurements of emanating power are of necessity comparative. In most cases, it is convenient to take a given weight of a thorium compound, kept under conditions as nearly as possible constant, and to compare the amount of emanation of the compound to be examined with this standard.

Radio-Activity — Part 191

In this way comparisons of the emanating power of thorium compounds have been made by Rutherford and Soddy[243], using an apparatus similar to that shown in Fig. 51 on page 240.

Radio-Activity — Part 191

A known weight of the substance to be tested was spread on a shallow dish, placed in the glass tube _C_. A stream of dry dust-free air, kept constant during all the experiments, was passed over the compound and carried the emanation into the testing vessel. After ten minutes interval, the current due to the emanation in the testing vessel reached a constant value. The compound was then removed, and the standard comparison sample of equal weight substituted; the saturation current was observed when a steady state was again reached. The ratio of these two currents gives the ratio of the emanating power of the two samples.