In urology, a Foley catheter is a brand name for one of many brands of urinary catheters (UC). Foleys and their namesakes are indwelling UC, often referred to as an IDCs (sometimes IDUCs) or the alternative type being an in/out catheters (with only a single tube and no valves, designed to go into the bladder, drain it, and come straight back out). The foley UC was named after Frederic Foley, who produced the original design in 1929. The UC is a flexible tube if it is indwelling and stays put, or rigid (glass (very rarely) or rigid plastic(usually)) if it is in/out, that a clinician, or the client themselves, often in the case of in/out UC, passes it through the urethra and into the bladder to drain urine.
Foley and similar brand catheters usually have two separated channels, or lumina (or lumen), running down its length. One lumen, opens at both ends, drains urine into a collection bag. The other has a valve on the outside end and connects to a balloon at the inside tip. The balloon is inflated with sterile water or saline it lies inside the bladder to stop it from slipping out. Manufacturers usually produce Foley catheters using silicone or coated natural latex. Coatings include polytetrafluoroethylene, hydrogel, or a silicone elastomer – the different properties of these surface coatings determine whether the catheter is suitable for 28-day or 3-month indwelling duration. There is a 3rd type of UC not mentioned above, that has 3 lumens for using for bladder washouts post prostate surgery, 1 lumen is for urine flow out, 1 lumen is for saline flow in (bladder washouts solution), and the 3rd is for the balloon to be inflated.
Indwelling catheters/IDCs should be used only when indicated, as use increases the risk of catheter-associated urinary tract infection (UTI) and other adverse effects. While female sex is generally recognised as a risk factor for UTIs, the differences in biological sex are reduced or even diminished while carrying catheters.
History
The name comes from the designer, Frederic Foley, a surgeon who worked in Boston, Massachusetts in the 1930s. His original design was adopted by C. R. Bard, Inc. of Murray Hill, New Jersey, who manufactured the first prototypes and named them in honor of the surgeon. There are now multiple companies worldwide who produced IDCs and in/out catheters, that are made of a range of materials, such is silicone, plastic, latex (although due to the rise in latex allergies, medical equipment made of latex is becoming less common). There are even still glass in/out catheters in use today (although very rare) as many older people who have been self catheterising for a very long time prefer them to the plastic ones, as there's no wastage. Currently in most countries the plastic in/out catheters have to be discarded after use. There is a study currently underway called "Single use versus reusable catheters in intermittent catheterisation for treatment of urinary retention: a protocol for a multicentre, prospective, randomised controlled, non-inferiority trial"
Types
Indwelling urinary catheters come in several types: Coudé (French for elbowed) catheters have a 45° bend at the tip that facilitates easier passage through an enlarged prostate. Councill tip catheters have a small hole at the tip so they can be passed over a wire. Three-way, or triple lumen catheters have a third channel used to infuse sterile saline or another irrigating solution. These are used primarily after surgery on the bladder or prostate, to wash away blood and blood clots. In/out catheters that are almost always made of a semi rigid plastic. Occasionally you may find older people still using glass catheters, although these are highly discouraged due to the dangers they pose, should something go wrong. The in/out catheters are simply a double open ended tube, with no valves. The average female would use a 10Fr to a 12Fr and the average male would use a 12Fr to 14Fr.
Sizes
The relative size of an indwelling urinary catheter is described using French units (Fr). Alternatively, the size of a 10 Fr catheter might be expressed as 10 Ch (Charriere units – named after a 19th century French scientific instrument maker, Joseph-Frédéric-Benoît Charrière). The most common sizes are 10 Fr to 28 Fr. 1 Fr is equivalent to 0.33 mm = .013" = 1/77" of diameter. Foley catheters are usually color coded by size with a solid color band at the external end of the balloon inflation tube, allowing for easy identification of the size. Note: Colors for French sizes 5, 6, 8, 10 may vary significantly if intended for pediatric patients. Color for French size 26 may also be pink instead of black.