The process of establishing documentary evidence demonstrating that a procedure, process, or activity carried out in testing and then production maintains the desired level of compliance at all stages. In the pharmaceutical industry, it is very important that in addition to final testing and compliance of products, it is also assured that the process will consistently produce the expected results. The desired results are established in terms of specifications for outcome of the process. Qualification of systems and equipment is therefore a part of the process of validation. Validation is a requirement of food, drug and pharmaceutical regulating agencies such as the US FDA and their good manufacturing practices guidelines. Since a wide variety of procedures, processes, and activities need to be validated, the field of validation is divided into a number of subsections including the following: Equipment validation Facilities validation HVAC system validation Cleaning validation Process Validation Analytical method validation Computer system validation
Similarly, the activity of qualifying systems and equipment is divided into a number of subsections including the following: Design qualification (DQ) Component qualification (CQ) Installation qualification (IQ) Operational qualification (OQ) Performance qualification (PQ)
History
The concept of validation was first proposed by two Food and Drug Administration (FDA) officials, Ted Byers and Bud Loftus, in 1979 in USA, to improve the quality of pharmaceuticals. It was proposed in direct response to several problems in the sterility of large volume parenteral market. The first validation activities were focused on the processes involved in making these products, but quickly spread to associated processes including environmental control, media fill, equipment sanitization and purified water production.
The concept of validation was first developed for equipment and processes and derived from the engineering practices used in delivery of large pieces of equipment that would be manufactured, tested, delivered and accepted according to a contract The use of validation spread to other areas of industry after several large-scale problems highlighted the potential risks in the design of products. The most notable is the Therac-25 incident. Here, the software for a large radiotherapy device was poorly designed and tested. In use, several interconnected problems led to several devices giving doses of radiation several thousands of times higher than intended, which resulted in the death of three patients and several more being permanently injured.
In 2005 an individual wrote a standard by which the transportation process could be validated for cold chain products. This standard was written for a biological manufacturing company and was then written into the PDA's Technical Report # 39,thus establishing the industry standard for cold chain validation. This was critical for the industry due to the sensitivity of drug substances, biologics and vaccines to various temperature conditions. The FDA has also been very focused on this final area of distribution and the potential for a drug substances quality to be impacted by extreme temperature exposure. 4.6. Accuracy: Accuracy of an analytical procedure is the closeness of test results obtained by that procedure to the true value. The accuracy of an analytical procedure shall be established across its range. 4.7. Precision: The precision of an analytical procedure expresses the closeness of agreement between a series of measurements obtained from multiple sampling of the same homogeneous sample under the prescribed conditions. 4.8. Method precision (Repeatability): Method precision carried out on different test preparation of a homogenous sample within short interval of time under same experimental conditions. 4.9. Intermediate precision (Ruggedness): Intermediate precision (Ruggedness) expresses within-laboratories variations i.e. different days, different analysts, different equipment etc. 4.10. Range: The range of an analytical procedure is the interval between the upper and lower concentration of analyte in the sample for which it has been demonstrated that the analytical procedure has a suitable level of precision, accuracy and linearity